Ratnagiri, Maharashtra · Plan reviewed 25 Oct 2026
WATER IS PART OF THE RECIPE

Know your water.
Then adjust.

Water pH tells you where it is now. Alkalinity helps explain how strongly it resists change. Neither replaces a measured finished-feed and drainage check.

No automatic acid dose. Water pH alone cannot determine grams of citric acid. Even an alkalinity result does not justify a fixed dose without a small measured titration. Concentrated nitric or phosphoric acid requires specialist handling.

Three samples. Different questions.

Source water

Test pH, EC, bicarbonate / alkalinity, calcium, magnesium, sodium, chloride and boron. The water contributes nutrients and salts before fertilizer is added.

Finished feed

Measure after all weighed salts and accurate trace dilutions are dissolved and the final water volume is reached. Working pH: 5.8–6.2. Do not use above 6.5. At 100%, total EC must be ≤1.9 mS/cm.

Representative drainage

Use a consistent sampling method and time. Compare drainage EC with the actual feed. A rising trend can signal accumulation; drainage chemistry is not identical to a lab substrate extract.

Collect comparable ordinary drainage

  1. Use calibrated EC and pH meters. Identify the same representative pot, including its emitter; compare additional pots when delivery is uneven.
  2. Sample during the normal irrigation routine. Record incoming feed EC/pH and applied litres. Do not add extra extraction water for this ordinary-drainage method.
  3. Collect drainage into a clean container over the same documented interval each time. Record drained litres, sampling time in IST and any rain entering the pot.
  4. Measure the fresh sample promptly. Record the method as ordinary drainage and keep the same routine and timing for later comparisons.
  5. Repeat an unexpected reading before interpreting the trend. Check the meter, emitter, collection method and root condition; resolve poor drainage before any corrective leach.
Methods are not interchangeable. Ordinary drainage is not standardized PourThru, saturated-media extract (SME) or a laboratory extraction. Follow the laboratory’s sampling and interpretation guidance for those methods. The numerical EC/pH rules here are working investigation triggers, not universal toxicity boundaries.

What changes the plan

MeasurementResponse
Drainage EC > feed +1.0, or >3.0 mS/cmHold feed; check drainage and roots. Flush with suitable water if drainage is free, then remeasure. Never flood a waterlogged pot.
Drainage pH <5.5Omit ammonium sulphate (or optional liquid stock C); review the trend and water source.
Drainage pH >6.5 twiceReview alkalinity and feed pH. Consider a suitable iron chelate with a verified label and dose. One reading is insufficient.
Finished feed outside pH 5.8–6.2Recheck the meter and small sample. Correct before applying; never use above pH 6.5.
Unknown measurementsMeasure before escalation. A blank value is not zero and cannot clear a safety gate.

Scale a measured citric-acid jar test

Use this only after testing the same water, fertilizer recipe and acid product on a small sample. Add dilute acid cautiously; allow the reading to stabilize.

Measured-test result

No acid amount is assumed. Enter your real test results to scale them.

Scaling is an initial reference. Add gradually and remeasure the full tank. Repeat when water, feed, product or conditions change. Never acidify the micronutrient stock.