Ratnagiri, Maharashtra · Plan reviewed 25 Oct 2026
WEIGH ACCURATELY · PREPARE WHAT YOU CAN USE
A practical batch. A measured start.
Check the smallest weight before preparing a dilution. Then compare the batch with actual garden consumption; extra decimal places do not make a weight measurable.
Rosa · a season in cinder
Choose one macro method. Weigh the macro salts directly and use boron-only + micro dilutions, or prepare complete A/B/C + micro stocks. Never combine the two. Grams measure solids; mL measures a liquid only after its stated preparation.
Check preparation weights
Your preparation check
Enter a verified minimum reliable scale weight to check the reference recipe. No ready-to-weigh sheet is issued while this is unknown.
Storage needs its own record
Scheduled replacement policies, not established stability. Four weeks for A/B/C and boron-only liquid, six weeks for micro liquid, and 2–3 days for final feed are unvalidated housekeeping limits. Prefer fresh feasible batches and obtain formulation-specific storage guidance before relying on multiweek storage. Record actual mixing date, initial pH and clarity, temperature and light exposure, then any changes. A clear bottle is not proof that every nutrient remains soluble. Never improvise acidification or a different stock formulation.
Keep the micro bottle dark and the feed tank opaque and covered. Do not increase irrigation to empty a bottle. A filter protects emitters; it cannot restore nutrients that have precipitated.
Direct method · reference recipes pending a precision check
Solid fertilizer reference
Per 10 L final feed at 100%. These quantities do not establish scale accuracy or safe storage.
Solid fertilizer
Grams per 10 L at 100%
What to check
Plain calcium nitrate
6.4 g
15.5% N, 19% Ca; no added boron
Potassium nitrate (NOP)
4.0 g
13-00-45
Monopotassium phosphate (MKP)
1.7 g
00-52-34
Magnesium sulphate
2.6 g dried OR 3.6 g Epsom
Dried grade and heptahydrate are different
Ammonium sulphate
0.3 g
Omit when drainage pH is below 5.5
Boron 20%
0.011 g equivalent
Tiny amount: use an accurately prepared dilution; never an ordinary kitchen scale.
Fe-EDTA 12% Fe
0.116 g equivalent OR 0.107 g at 13% Fe
Use the correct grade and accurately prepared micronutrient dilution.
ZnSO₄·H₂O · 33% Zn
0.0069 g equivalent
Tiny trace amount: accurately prepared dilution.
MnSO₄·H₂O
0.0085 g equivalent
Tiny trace amount: accurately prepared dilution.
CuSO₄·5H₂O
0.0019 g equivalent
Tiny trace amount: accurately prepared dilution.
Na₂MoO₄·2H₂O
0.0012 g equivalent
Tiny trace amount: accurately prepared dilution.
Weigh each solid fertilizer separately in grams, using a scale accurate enough for the amount.
Start with ample clean working water. Dissolve each salt separately into that water, stirring fully between additions. Never bring calcium into contact with concentrated phosphate or sulphate.
Boron and trace-element masses are tiny equivalents: use the separately labelled boron-only and micronutrient dilutions. Do not guess, round to a scoop, or use jar B as boron alone after weighing the other salts.
Omit ammonium sulphate when drainage pH is below 5.5.
Top up to the final water volume. Measure finished-feed EC and pH before use.
Boron-only and micronutrient dilution references
These dilutions accompany direct-weighed macro salts. Do not also add A/B/C stocks.
Boron-only dilution · separate from jar B
Weigh 1.1 g Boron 20%, dissolve in water and make up to 1 L final liquid. Label it “Boron only”.
Only after preparing this liquid, use 10 mL per 10 L feed at 100% (7.5 mL at 75%). This supplies 0.011 g of solid product equivalent at 100%. Do not add the tiny boron solid again.
Never confuse this with jar B. Jar B contains macro salts too and would duplicate the dry recipe.
Micronutrient dilution · for tiny trace weights
Weigh Fe-EDTA 12% 11.6 g (or 13% 10.7 g), ZnSO₄·H₂O 33% Zn 0.69 g, MnSO₄·H₂O 0.85 g, CuSO₄·5H₂O 0.19 g and sodium molybdate dihydrate 0.12 g. Dissolve in distilled water; make up to 1 L final liquid.
Only then use 10 mL of this prepared liquid per 10 L feed at 100% (7.5 mL at 75%). It supplies the listed tiny trace equivalents; do not add those solids again. It contains no boron. Keep dark; schedule replacement at six weeks; stability is unverified; do not acidify.
Alternative A/B/C method · reference recipes pending a precision check
Preparation reference only. Use the check above before weighing. Make each separate bottle to its final liquid volume; keep A and B concentrates separate. Never round an unmeasurable mass.
Optional liquid stock A
Weigh plain calcium nitrate 64 g + NOP 20 g. Dissolve and make up to 1 L final liquid stock.
Only this prepared liquid is measured as 100 mL per 10 L feed at 100% (75 mL at 75%). It is not 100 mL of powder. Four weeks is a scheduled replacement policy; stability is unverified.
Optional liquid stock B
Weigh dried MgSO₄ 26 g (or Epsom 36 g), MKP 17 g, NOP 20 g, Boron 20% 0.11 g. Dissolve and make up to 1 L final liquid stock.
Only this prepared liquid is measured as 100 mL per 10 L feed at 100% (75 mL at 75%). Four weeks is a scheduled replacement policy; stability is unverified. B supplies several nutrients; never add it as boron alone to the dry recipe.
Optional liquid stock C
Weigh ammonium sulphate 30 g. Dissolve and make up to 1 L final liquid stock.
Only this prepared liquid is measured as 10 mL per 10 L feed at 100% (7.5 mL at 75%). Omit below drainage pH 5.5. C is a 1,000× stock; A/B are 100×.
Prepared micronutrient dilution
Weigh Fe-EDTA 12% 11.6 g (or 13% 10.7 g), ZnSO₄·H₂O 33% Zn 0.69 g, MnSO₄·H₂O 0.85 g, CuSO₄·5H₂O 0.19 g, sodium molybdate dihydrate 0.12 g. Dissolve in distilled water and make up to 1 L final liquid.
This prepared 1,000× liquid supplies the tiny trace weights at 10 mL per 10 L feed at 100% (7.5 mL at 75%). It contains no boron. Keep dark; schedule replacement at six weeks; stability is unverified; do not acidify.
Only after accurate preparation
Only after dissolving the specified gram weights and making each separate bottle up to its final stock volume, measure the prepared liquid in mL.
Start with nearly full working water. Add B, stir, add A, stir, add C if appropriate, then micro, stirring between additions.
Top up to final feed volume and measure EC/pH. Never mix A and B concentrates directly. Do not also add the direct-weigh dry recipe.